Search results for "flexible load"
showing 6 items of 6 documents
Impact of Demand Response Control Logic on Isolated Island's Distribution Networks
2019
The work presents the results of a study regarding the impact of some Demand Response control logics on an isolated distribution network. The proposed control is divided into precise steps in which the coordination between the general aggregator controller and the single local Energy Management Systems is developed and illustrated with details. The control is applied to the flexible loads and to the storage systems of photovoltaic plants installed at the end-users' houses and connected to the network. The study is carried out delivering a suitable network model of the island's system, with the implementation of load profiles for all the loads of the network for a total simulation time of 24…
Effects of Demand Side Management on the Operation of an Isolated LV Microgrids
2019
The work presents the results of a study regarding the impact of Demand Side Management actions on flexible loads distributed at the domestic end-users' facilities in an isolated low voltage microgrid. Aim of the research study is to evaluate how the implementation of local control actions on the end-user's side can impact on the operation of the isolated microgrid. The Demand Side Management is applied by each domestic user to optimize the operation of its own resources following well-defined operative steps. The study is carried out implementing a suitable model of the microgrid in Neplan environment, while the daily controlled load profiles of the end-users are evaluated using the Montec…
Swing options in commodity markets: a multidimensional Lévy diffusion model
2013
Author's version of an article in the journal: Mathematical Methods of Operations Research. Also available from the publisher at: http://dx.doi.org/10.1007/s00186-013-0452-7 We study valuation of swing options on commodity markets when the commodity prices are driven by multiple factors. The factors are modeled as diffusion processes driven by a multidimensional Lévy process. We set up a valuation model in terms of a dynamic programming problem where the option can be exercised continuously in time. Here, the number of swing rights is given by a total volume constraint. We analyze some general properties of the model and study the solution by analyzing the associated HJB-equation. Furthermo…
A bottom-up approach for the evaluation of the flexible quota of aggregated loads
2015
The paper presents a bottom-up approach for building the aggregated load profile of numerous passive/active users connected to the low voltage electrical system. The approach is based on the Monte Carlo method and on the knowledge of the single electric and thermal loads, generators and thermal and geometrical characteristics of the building of the single end-user. The method proposed is able to differentiate the quota of flexible and not flexible aggregate load.
Demand Response for Integrating Photovoltaic Plants in Lampedusa Island
2021
This paper presents the results of a simulation study concerning different Demand Response logics applied to Electric Storage Water Heaters on the island of Lampedusa. Electric Storage Water Heaters are the devices that are primarily used on the island to produce domestic hot water. Starting from measured load profiles collected in Lampedusa, a domestic hot water consumption profile was derived, to simulate the energy usage of the Storage Water Electric Heaters during the day. This work was carried out as a preliminary feasibility study for the BloRin project, financed by cohesion funds in the Sicilian region. According to the project, which also includes the installation of domestic photov…
On the Impact of Heat Pumps Electric Load on the Power Consumption of Lampedusa
2020
The present paper reports the results of a simulation study regarding the impact of the adoption of heat pumps for domestic hot water production in the island of Lampedusa (Italy). In the study, it has been assumed to replace electric storage water heaters with heat pumps at every dwelling of the about four thousand domestic end-users of the island and, in addition, to control the heat pump operation in order to enhance some parameters that characterize the quality of the generation and distribution system of the island (power peak, energy losses and voltage drop). According to the results of the simulations, while the replacement of electric storage water heaters with heat pumps is able to…